Rohöldestillationskolonne


crude oil
distillation column

ASTM D 2892

Scope

  • distillation (crude oil)
  • debutanisation (collection of C3/C4-hydrocarbons at – 45 °C)

Operation parameters

  • glass column with fraction collection, batch operation
    • pressure: vacuum (2 mmHg) up to ambient pressure
    • temperature: 15 °C up to 400 °C
  • tanks: 4 L, 6 L and 10 L (minimum 2 L)
  • Collecting of fractions (max. 20 cuts)

Contact

Christian Schwarz

Christian Schwarz

Deputy Manager Mini Plant Laboratory

Rohöldestillationskolonne


crude oil
distillation column

ASTM D 5236

Scope

  • distillation (crude oil)
  • distillation of high-boiling components

Operation parameters

    • glass column with fraction collection, batch operation
      • pressure: vacuum (0,1 mmHg) up to ambient pressure
      • temperature: 15 °C up to 565 °C
    • tanks: 4 L, 6 L and 10 L (minimum 2 L)
    • Collecting of fractions (max. 20 cuts)